The Complete Guide To Sigenergy SigenStor Error Codes

All 36 Sigenergy error codes in plain English, across the energy controller, battery modules, gateway and EV charger: what each one means, how urgent it is, how to restart your SigenStor safely, and whether it can be repaired.

Jump to the 36 Sigenergy error codes

Why a Sigenergy error code is worth sorting now

A Sigenergy alarm means part of your SigenStor has paused or stopped: the solar input, the battery, the gateway that switches you to backup, or the EV charger. While it is down, the power you would have made or stored comes from the grid at the full price. A few alarms are about safety, such as 1002 for weak insulation on the solar wiring and 1017 for current leaking to earth.

Sigenergy is a new-generation hybrid and battery system, on Australian homes since about 2023, and it is built from modules, so a fault can often be dealt with by swapping the part that failed rather than the whole system. Plenty of alarms are not faults at all: a grid trip that clears itself, an emergency stop button that someone has pressed, or a module that needs a firmware update to match the rest.

Sorting an alarm early keeps the battery cycling and your bills where you expected them. An alarm that is left to repeat can keep the battery or the backup out of action for weeks without anyone noticing, and the savings you bought the system for go with it.

Find your code in the table below to see what it means and how urgent it is. If your home is in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland, our own licensed electricians will go through it with you over the phone for free before anyone drives out. Check your postcode to see if we cover you.

Which Sigenergy system do you have?

Each part of a Sigenergy system carries its own label, and its alarms appear in the mySigen app. The first digit of the alarm number tells you which part raised it.

  • Sigen Energy Controller: the hybrid inverter part of the SigenStor, where the solar connects. Its alarms start with 1.
  • SigenStor battery modules: the battery, made up of modules with their own heater. Their alarms start with 2.
  • Sigen Energy Gateway: the box that switches the house between the grid and backup. Its alarms start with 3.
  • Sigenergy EV charger: the built-in EV charger. Its alarms start with 5.

All 36 Sigenergy error codes, explained

Sigenergy shows each alarm in the mySigen app as a four-digit number and a name, such as 1011 Grid overvoltage, often with an ID that narrows down the cause. The first digit is the part of the system: 1 the energy controller, 2 the battery, 3 the gateway and 5 the EV charger. Every code is below, grouped by what it relates to: the grid and mains supply, the panel input and power output, insulation and earth faults, heat and cooling fans, the unit's internal hardware, the battery, and monitoring. The number in brackets after each code's name is its source in the reference list.

  • Stop and call A safety or hardware fault that nobody can fix from a phone. Do the one safe restart at most, then call.
  • Worth a look Something to check or restart safely. If it comes back, book a visit.
  • Wait and watch The inverter has paused for a reason outside itself, usually the grid or the light, and restarts on its own.

We always err on the cautious side: when a code sits between two ratings, it gets the higher one.

Grid and mains supply error codes 6 codes

The mains grid coming into the unit: voltage, frequency and outages. Many of these are the grid, not the inverter, and clear on their own. 1 stop and call, 5 wait and watch.

Error codeWhat it meansWhat to do
1010 Grid power outageSigenergy 1010 Grid power outage No grid detected[1]

The energy controller cannot see mains power on its grid side. Usually the power is out or the solar supply main switch or breaker in the switchboard is off; a system with backup keeps running the house from the battery. It reconnects by itself once the grid is back. If it stays while the neighbours have power, the switchboard and AC connections need checking.

Safe steps in the lookup
Wait and watch
1011 Grid overvoltageSigenergy 1011 Grid overvoltage Grid voltage too high[1]

The mains voltage at the energy controller rose above the limit it is allowed to export at (the app shows Level I, II or III for how far over), so it disconnected. It reconnects by itself once the grid settles. If it happens most sunny afternoons the street voltage is high and Sigenergy's advice is to measure it and contact the network. The gateway logs the same per phase as 3009.

Safe steps in the lookup
Wait and watch
1012 Grid undervoltageSigenergy 1012 Grid undervoltage Grid voltage too low[1]

The mains voltage at the energy controller dropped below the limit, often a brownout, a heavy load starting nearby or a loose AC connection, and it disconnected. It reconnects by itself once the voltage recovers. On a three-phase system a missing phase shows as 3008 Grid phase loss and needs the grid-side wiring checked.

Safe steps in the lookup
Wait and watch
1013 Grid overfrequencySigenergy 1013 Grid overfrequency Grid frequency out of range[1]

The grid frequency went above (1013) or below (1014) the energy controller's limits for a moment, or changed too fast (1027 Grid frequency unstable), and it disconnected. It reconnects by itself once the grid is steady. If it happens often, Sigenergy's advice is to measure the frequency and contact the network.

Safe steps in the lookup
Wait and watch
1015 Grid voltage imbalanceSigenergy 1015 Grid voltage imbalance Three-phase grid unbalanced[1]

On a three-phase system the three phases differ too much in voltage or timing, so the energy controller disconnected. It reconnects by itself once the grid settles. If it keeps happening, Sigenergy's advice is to measure each phase and contact the network, since the cause is on the supply side.

Safe steps in the lookup
Wait and watch
1024 Abnormal phase sequenceSigenergy 1024 Abnormal phase sequence Three-phase wiring in the wrong order[1]

On a three-phase system the phases are connected in the wrong order at the energy controller (1024), at the gateway's grid input (3006), load side (3007) or generator input (3012). The system will not run until two phases are swapped, which is an installer job. It only appears at commissioning or after switchboard work.

Safe steps in the lookup
Stop and call

Panel input and power output error codes 4 codes

The DC input from the panels and the power the unit puts out: string voltage, low light, overloads and output limits. 3 stop and call, 1 worth a look.

Error codeWhat it meansWhat to do
1006 PV string overvoltageSigenergy 1006 PV string overvoltage Solar string voltage too high[1]

The open-circuit voltage of a solar string is above the energy controller's maximum input, which Sigenergy puts down to too many panels in series. It shows on cold, clear mornings. The controller protects itself and waits for the voltage to drop; the lasting fix is fewer panels in that string, which is an installer job. The app's ID number says which string. Over-voltage, over-current and short-circuit faults can damage hardware, so we treat them as a call.

Safe steps in the lookup
Stop and call
1007 PV string reversely connectedSigenergy 1007 PV string reversely connected Solar string polarity reversed[1]

A solar string is connected with positive and negative the wrong way round. The energy controller will not use that string until the wiring is corrected. It normally shows at commissioning or after work on the roof, and the fix is on the DC side, which is an installer job done with the DC isolator open once the string current is low.

Safe steps in the lookup
Stop and call
1008 PV string sinking currentSigenergy 1008 PV string sinking current Solar string drawing current[1]

One string is pulling current instead of producing it, which happens when it is weaker than the strings it shares an input with: fewer panels, heavy shading, dirt, or a different orientation. Sigenergy's fix is to match the panel count, clear the shading or clean the panels, which may need the installer to rework the string.

Safe steps in the lookup
Worth a look
1021 Inverter AC side voltage abnormalSigenergy 1021 Inverter AC side voltage abnormal Backup output overloaded or abnormal[1]

While running the house without the grid, the backup output went out of range: too much load (ID1), a short on the backup wiring (ID2), or voltage or frequency off because of a very large load, a generator, or the gateway's inverter-side switch being off (IDs 3 to 6). Switch off heavy appliances and it recovers; a short or a repeat needs an electrician. The gateway logs load-side faults as 3011. Over-voltage, over-current and short-circuit faults can damage hardware, so we treat them as a call.

Safe steps in the lookup
Stop and call

Panels, insulation and earth faults error codes 6 codes

Insulation, earth and leakage faults on the solar panel side. These are safety faults: live DC wiring may be leaking to earth somewhere on the roof. 6 stop and call.

Error codeWhat it meansWhat to do
1002 Low insulation resistanceSigenergy 1002 Low insulation resistance Panel insulation fault[1]

The energy controller found too little insulation between the solar wiring and earth: Sigenergy's causes are a PV string shorted to earth or installed somewhere permanently damp, so water in a connector, a chafed cable or a damaged panel. An alarm only on rainy mornings is usually moisture; one that stays is a safety issue and needs an electrician. The EV charger raises the same fault as 5102.

Safe steps in the lookup
Stop and call
1005 System grounding faultSigenergy 1005 System grounding fault Earth connection missing[1]

The system cannot see a good earth (protective earth) connection. Sigenergy's cause is simply that the PE cable is not connected or not earthed; the gateway's version (3005) adds a high voltage between neutral and earth or live and neutral swapped. The system will not run safely without an earth, so it is an electrician's check.

Safe steps in the lookup
Stop and call
1009 AFCI faultSigenergy 1009 AFCI fault Arc fault on the solar wiring[1]

The energy controller's arc detector heard the electrical signature of a DC arc on a solar string, which is a fire risk. It shuts the solar input down. Sigenergy's causes are a damaged DC cable or a poor connection at a string connector; after repair the fault is cleared in the mySigen app. Treat it as urgent and do not keep clearing it.

Safe steps in the lookup
Stop and call
1017 Leak current out of limitSigenergy 1017 Leak current out of limit Residual current trip[1]

The energy controller measured current leaking to earth above its protection threshold, usually damaged cable insulation, water in a connector or high humidity on the solar side. Sigenergy says a one-off clears itself, but because this is an electrical safety trip a repeat needs an electrician. The gateway's version (3004) points at a load with damaged insulation while running on backup.

Safe steps in the lookup
Stop and call
1020 Abnormal AFCI self-checking circuitSigenergy 1020 Abnormal AFCI self-checking circuit Arc detector self-test failed[1]

The circuit that listens for DC arcs failed its own self-test, as opposed to finding an arc. The energy controller will not run its solar input without a working arc detector. Sigenergy's step is to clear the self-test fault in the app and restart; if it comes back, the detection board needs a service call.

Safe steps in the lookup
Stop and call
1025 Short circuit to PESigenergy 1025 Short circuit to PE Grid phase shorted to earth[1]

The energy controller sees one of the grid phases shorted to earth on the AC wiring. It will not connect until the wiring is checked, which is an electrician's job and should not be reset by the owner.

Safe steps in the lookup
Stop and call

Heat and cooling fans error codes 2 codes

Over-temperature, heat derating and the cooling fans. Heat faults are taken seriously: a unit that cannot cool itself can be a fire risk. 2 stop and call.

Error codeWhat it meansWhat to do
1003 Over-temperatureSigenergy 1003 Over-temperature Energy controller over-temperature[1]

The energy controller (1003) or the gateway (3002) got too hot, usually a hot afternoon in direct sun or poor airflow where it is mounted, and it cut back or paused. Sigenergy says it restarts by itself once the inside cools. If it happens often or in mild weather, the location, ventilation or a fan needs checking. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call.

Safe steps in the lookup
Stop and call
5001 Equipment protection (EV charger)Sigenergy 5001 Equipment protection (EV charger) EV charger stopped charging[1]

The built-in EV charger stopped for a protection reason: grid voltage out of range, overload, a short, leakage current or a ground or wiring fault (5001, the ID says which), the charger or plug too hot (5003), a cable it does not recognise (5004) or a handshake problem with the car (5105). First steps: stop, unplug, let it cool, try again; leakage, ground and wiring faults need an electrician. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call.

Safe steps in the lookup
Stop and call

Internal hardware and safety checks error codes 8 codes

The unit's own electronics: relays, sensors, the DC bus, memory and its self-checks. Nearly all of these need an electrician. 6 stop and call, 1 worth a look, 1 wait and watch.

Error codeWhat it meansWhat to do
1004 Equipment faultSigenergy 1004 Equipment fault Energy controller hardware fault[1]

A module inside the energy controller has failed its check: the power module, control module, auxiliary power supply, PID module, monitoring module, heating film or the external fan (IDs 1 to 7). Sigenergy allows one full power-down and restart; if the alarm comes back a part inside needs replacing, which Sigenergy handles through its service partner.

Safe steps in the lookup
Stop and call
1016 DC component of output current out of limitSigenergy 1016 DC component of output current out of limit DC injection into the grid[1]

The energy controller measured a small DC component in its AC output, which the grid rules do not allow, and disconnected. Sigenergy says a one-off comes from a sudden change in conditions and clears by itself. If it happens often or stays, the output stage needs a service check. DC on the AC side is a protection fault, so we treat it as a call.

Safe steps in the lookup
Stop and call
1019 Internal protectionSigenergy 1019 Internal protection Internal protection tripped[1]

One of the energy controller's internal limits tripped: an MPPT or output overcurrent, the DC bus over its voltage or out of balance, or the internal control protection (the app's ID says which). The battery (2008) and EV charger (5106) have the same family. Sigenergy says a one-off clears by itself; if it happens often or stays, the unit needs a service check.

Safe steps in the lookup
Stop and call
1023 Abnormal wiringSigenergy 1023 Abnormal wiring AC wiring fault[3][4]

The energy controller found a problem with its AC wiring: the connections at the AC port are wrong or loose (newer firmware may name a disconnected neutral), or the gateway's internal switch is off. It normally appears at commissioning or after switchboard work. Sigenergy's steps are standby, isolate the grid switch, wait for power-off and check the wiring, which is an installer job.

Safe steps in the lookup
Stop and call
1026 Soft start failureSigenergy 1026 Soft start failure Start-up failed[1]

The energy controller tried to ramp up and connect but did not complete its soft start. Sigenergy says a one-off comes from a sudden change in conditions and the unit tries again by itself; if it happens often or it never connects, it needs a service check.

Safe steps in the lookup
Worth a look
3003 Equipment fault (gateway)Sigenergy 3003 Equipment fault (gateway) Gateway hardware fault[1]

The Sigen Energy Gateway (the box that switches the house between grid and backup) has reported a fault in its own hardware: its auxiliary power, internal communication, control circuit, or the grid, generator or neutral-earth contactor stuck open or closed (IDs 1 to 9). The house may lose its backup switching. Sigenergy allows one full power-down and restart; a repeat needs a service call.

Safe steps in the lookup
Stop and call
5002 Equipment fault (EV charger)Sigenergy 5002 Equipment fault (EV charger) EV charger hardware fault[1]

The built-in EV charger has reported a fault in its own hardware: its leakage detection circuit, relay, control circuit, auxiliary power, the plug's electronic lock or its indicator board (5002), or on the DC charger its fan, power or insulation-detection circuit (5104). Sigenergy allows one restart of the charger; if the alarm comes back it is a service call. The solar and battery keep working.

Safe steps in the lookup
Stop and call
3009 Grid failure (gateway)Sigenergy 3009 Grid failure (gateway) Gateway sees grid or generator out of range[1]

The Sigen Energy Gateway measured the grid (3009) or a connected generator (3010) outside its voltage or frequency limits on one or more phases. Sigenergy says to wait for the grid to return to normal and the alarm clears itself; if the grid is fine and it stays, the grid or generator wiring at the gateway needs checking.

Safe steps in the lookup
Wait and watch

Battery error codes 6 codes

The battery, its management system and its state of charge. These only appear on systems with a battery connected. 4 stop and call, 1 worth a look, 1 wait and watch.

Error codeWhat it meansWhat to do
2002 Energy storage module low insulation resistanceSigenergy 2002 Energy storage module low insulation resistance Battery insulation fault[1]

A battery module measured too little insulation between itself and its housing, which Sigenergy puts down to the module being shorted to the case: water, damage or an internal fault. Sigenergy allows one full power-down and restart from the app; if the alarm returns the module needs a service call. Do not keep restarting it.

Safe steps in the lookup
Stop and call
2003 Over-temperature (battery)Sigenergy 2003 Over-temperature (battery) Battery over-temperature[1]

A battery module, or the power stage that charges it, got too hot and the system paused charging or discharging. It resumes once it cools. A hot afternoon in direct sun or poor airflow is the usual cause; if it happens often or in mild weather, the location or the module needs checking. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call.

Safe steps in the lookup
Stop and call
2004 Equipment fault (battery)Sigenergy 2004 Equipment fault (battery) Battery hardware fault[1]

A battery module has reported a fault in its own hardware: its control circuit, the battery module itself, its auxiliary power supply, the link between modules, or a stuck switch button (IDs 1 to 5). Sigenergy allows one full power-down and restart from the app; if the alarm comes back the module needs replacing through Sigenergy's service partner.

Safe steps in the lookup
Stop and call
2005 Under-temperatureSigenergy 2005 Under-temperature Battery too cold[1]

A battery module is too cold to charge or discharge safely, so it pauses. The SigenStor battery has its own heater: Sigenergy says to wait for the system to warm itself to its working range, after which it recovers by itself. A garage or shaded wall in a frosty area is the usual cause; if it stays after the day warms, the heater or a sensor needs checking.

Safe steps in the lookup
Wait and watch
2006 Battery module over-voltageSigenergy 2006 Battery module over-voltage Battery module overvoltage[1]

A battery module, or cells inside it, has been charged above its safe voltage, so the system has stopped charging it. Sigenergy's instruction is to go to the Support troubleshooting page or contact the local service; it is not something to clear yourself, since it points to a balancing or charge-control fault. Over-voltage, over-current and short-circuit faults can damage hardware, so we treat them as a call.

Safe steps in the lookup
Stop and call
2007 Battery module under-voltageSigenergy 2007 Battery module under-voltage Battery module undervoltage[1]

A battery module, or cells inside it, has dropped below its safe voltage, so the system has stopped discharging it. Sigenergy says this follows a long time in storage or switched off, for example after a long blackout or a system left off for weeks. Sigenergy's instruction is to go to the Support troubleshooting page or contact the local service so the battery can be recovered safely.

Safe steps in the lookup
Worth a look

Monitoring, communication and settings error codes 4 codes

Monitoring, Wi-Fi, meters, communication between parts of the system, settings and firmware. Usually not a hardware fault, but the system may stop reporting. 1 stop and call, 2 worth a look, 1 wait and watch.

Error codeWhat it meansWhat to do
1001 Software version mismatchSigenergy 1001 Software version mismatch Firmware versions do not match[1][2]

The software inside the parts of the SigenStor does not match: the energy controller (1001), a battery module (2001), the gateway (3001) or the EV charger (5101) is on a different version from the rest, usually after an interrupted update or a new module. The system may run in a limited way. The fix is another update, which the installer or Sigenergy pushes remotely through mySigen.

Safe steps in the lookup
Worth a look
1018 Communication faultSigenergy 1018 Communication fault Communication lost[1]

Part of the system has stopped talking to the rest: the 4G dongle (ID1, no data or SIM), the internal CAN link (ID2), the energy meter (ID3) or the gateway (ID4); the gateway logs its own view as 4001. Solar and battery usually keep working, but the app may show no data or the battery may not know what the house is using. Sigenergy's steps: check the 4G data and dongle, restart, check the cables. Internal and hardware faults need testing with the right instruments, so we treat them as a call.

Safe steps in the lookup
Stop and call
1022 Manual operation protectionSigenergy 1022 Manual operation protection Emergency stop pressed[1][2]

Someone pressed the emergency stop (rapid shutdown) button, so the system has shut itself down on purpose; the gateway reports the same as 3013. Nothing is faulty. Once you are sure there is no safety problem on site, release the button (on earlier firmware) or follow the app's prompt and the system restarts.

Safe steps in the lookup
Wait and watch
3014 Bypass Switch OpenSigenergy 3014 Bypass Switch Open Gateway bypass switch position[1]

The gateway's bypass switch, which lets an electrician feed the house straight from the grid during service, is in the wrong state: it will not close (3014) or has been left on (3015), so the system is not controlling the house supply. The house still has grid power. Sigenergy's steps are to check the gateway is working and, if it is, switch the bypass off again; an installer does this.

Safe steps in the lookup
Worth a look

Got a Sigenergy error code? Free phone diagnosis in our service area

Our own licensed electricians cover Greater Adelaide and regional SA, and from North Brisbane up through the Sunshine Coast to Gympie. Check your postcode, then read us the code and tell us the install year. If it needs a visit, the callout is credited against the work.

How to restart a SigenStor safely

Sigenergy's own restart starts and finishes in the mySigen app. First check nobody needs the system off, such as trades on site or a fire or flood concern. Then try it once, in this order:

  1. Shut the system down from the mySigen app.
  2. Switch the AC off at the switchboard.
  3. Switch the DC isolator off.
  4. Wait five minutes.
  5. Switch the DC isolator back on, then the AC.
  6. Start the system again from the mySigen app.

If the emergency stop button has been pressed, release it or follow the mySigen app's prompt and the system restarts itself. Never open the unit or touch the wiring. Never restart anything that smells hot or shows scorch marks. If the alarm comes back after one restart, stop and call.

Sigenergy SigenStor service or repair?

On a visit, our electricians test the whole system first: insulation resistance on every string, earth continuity, DC string voltages and currents, the AC supply and its phase order, the battery modules, the gateway and the alarm history with its IDs. A 1005 grounding fault is usually a missing earth connection rather than a failed controller, and a 1008 alarm means one string is weaker than the one it shares an input with, which is a panel layout fix.

Because a SigenStor is built from modules, a confirmed hardware fault usually means swapping the part that failed rather than replacing the system. If your system is still under warranty, talk to us first and we will tell you which way it needs to go. The callout fee is credited against any repair we do.

We do this work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland only. Outside those areas, everything above still applies: take the code, its meaning and the urgency to a licensed electrician near you.

Where these Sigenergy error codes come from

Every Sigenergy code on this page was read from the maker's own manual. The numbers match the references in the code table.

  1. [1]
    Sigenergy Alarm List V04 (release 2024-11-18)35 codes, from the maker's own document
  2. [2]
    Alarm List V03 (2024-03-29)2 codes, from the maker's own document
  3. [3]
    Sigenergy Alarm List V03 (release 2024-03-29)1 code, from the maker's own document
  4. [4]
    Zac Power Sigenergy SigenStor error codes page (newer ID names, secondary)1 code, from the maker's own document

Tables last updated

Sigenergy error code questions, answered

How do I read a Sigenergy error code?

Open the alarm in the mySigen app and note the four-digit number, the name and any ID shown with it. The number tells you which part raised it and what kind of fault it is, and the ID narrows the cause, for example which internal module failed under 1004. Search the number above to find its row.

What does Sigenergy 1011 Grid overvoltage mean?

1011 Grid overvoltage is “grid voltage too high”. The mains voltage at the energy controller rose above the limit it is allowed to export at (the app shows Level I, II or III for how far over), so it disconnected. It reconnects by itself once the grid settles. If it happens most sunny afternoons the street voltage is high and Sigenergy’s advice is to measure it and contact the network. The gateway logs the same per phase as 3009. We rate it wait and watch. See it in the table.

What does Sigenergy 1002 Low insulation resistance mean?

1002 Low insulation resistance is “panel insulation fault”. The energy controller found too little insulation between the solar wiring and earth: Sigenergy’s causes are a PV string shorted to earth or installed somewhere permanently damp, so water in a connector, a chafed cable or a damaged panel. An alarm only on rainy mornings is usually moisture; one that stays is a safety issue and needs an electrician. The EV charger raises the same fault as 5102. We rate it stop and call. See it in the table.

Do you cover my area?

We work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland. Check your postcode to be sure. Outside those areas, this page still tells you what your code means and how urgent it is, and a licensed electrician near you can take it from there.

What does it cost to have a Sigenergy looked at?

For homes in our service area, the phone diagnosis is free. If it needs a visit, there is a callout fee, and it is credited against any repair or replacement we do.

Will you work on a Sigenergy you did not install?

Yes, if it is in our service area. Most of our repair work is on systems someone else installed. We test the whole system, not just the unit on the wall.

Is my Sigenergy still under warranty?

It depends on when it was installed and what has failed. Talk to us first and we will tell you whether it is a warranty matter before anything is replaced.

Someone pressed the Sigenergy emergency stop. What now?

Nothing is broken: alarm 1022 means the system shut itself down on purpose. Once you are sure there is no safety problem on site, release the button or follow the prompt in the mySigen app, and the system restarts itself.