When a Zeversolar puts an error number on its screen, it has usually stopped exporting. Each sunny day it stays that way, you pay full price for power your roof should be making. A few of its numbers, like 36 and 38, mean current may be leaking from the solar wiring to earth, and those are safety faults rather than lost savings.
Zeversolar, sold earlier as Eversolar, ceased business in December 2019. There is no warranty and there are no parts, so when the fault is inside the inverter, replacing it is the realistic path. Not every number means that. A wet connector, a tripped solar supply main switch or a grid voltage trip can all put a code on the screen, and none of them needs a new inverter.
A quick diagnosis tells you which kind of fault you have before a whole season of generation slips by. If the inverter is finished, the panels usually stay, and you can choose a straight swap or a hybrid that takes a battery now or later. If the trouble is on the roof, sorting it now stops a damp connector tripping the system every time it rains.
Find your code in the table below to see what it means and how urgent it is. If your home is in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland, our own licensed electricians will go through it with you over the phone for free before anyone drives out. Check your postcode to see if we cover you.
The model is on the label on the side of the inverter. The ZeverCloud app will not tell you, because its servers were switched off in late 2021.
A Zeversolar shows a fault as a plain number on its screen, which is why owners search for Error 38 or error code 3. Waiting, No display and the ZeverCloud row are not maker codes, but they are what owners most often type in. Every code is below, grouped by what it relates to: the grid and mains supply, the panel input and power output, insulation and earth faults, the unit's internal hardware, and monitoring. The number in brackets after each code's name is its source in the reference list.
We always err on the cautious side: when a code sits between two ratings, it gets the higher one.
The mains grid coming into the unit: voltage, frequency and outages. Many of these are the grid, not the inverter, and clear on their own. 5 wait and watch.
| Error code | What it means | What to do |
|---|---|---|
| 33Zeversolar error code 33 | Grid frequency out of range[1] The mains frequency drifted outside the inverter's limits, so it disconnected. It reconnects by itself once the grid settles; only frequent repeats need a look. Safe steps in the lookup |
Wait and watch |
| 34Zeversolar error code 34 | Grid voltage out of range[1] The mains voltage at the inverter went outside its limits, most often too high on a sunny afternoon, so it disconnected. It reconnects on its own; daily repeats mean the grid voltage or the AC cable needs checking. Safe steps in the lookup |
Wait and watch |
| 35Zeversolar error code 35 | No grid detected[1] The inverter cannot see the mains. A tripped solar supply main switch, a blackout, a blown fuse or a damaged AC cable are the usual causes. Safe steps in the lookup |
Wait and watch |
| 48Zeversolar error code 48 | Ten-minute average voltage high[5] The grid voltage averaged over ten minutes was above the limit, so the inverter disconnected. It reconnects on its own; if it happens most afternoons the grid voltage at your house is running high. Best effort · from a secondary copySafe steps in the lookup |
Wait and watch |
| WaitingZeversolar Waiting | Waiting, checking or reconnect[1] These are normal states, not faults: the inverter is waiting for enough sunlight, checking the grid before it connects, or reconnecting after a fault cleared. If it sits on Waiting all day in good sun, the array voltage is too low to start. Safe steps in the lookup |
Wait and watch |
The DC input from the panels and the power the unit puts out: string voltage, low light, overloads and output limits. 2 worth a look.
| Error code | What it means | What to do |
|---|---|---|
| 37Zeversolar error code 37 | Solar array voltage too high[1] The voltage coming from the panels is above the inverter's maximum. It can happen on a cold bright morning on a system that was wired close to the limit; if it keeps appearing the strings need checking. Safe steps in the lookup |
Worth a look |
| No displayZeversolar No display | No display, no lights[4] The inverter has no power at all. On a sunny day that means the supply has been cut by a tripped switch or isolator, or the inverter's own power supply has failed, which on a Zeversolar is the end of the unit. Best effort · from a secondary copySafe steps in the lookup |
Worth a look |
Insulation, earth and leakage faults on the solar panel side. These are safety faults: live DC wiring may be leaking to earth somewhere on the roof. 4 stop and call.
| Error code | What it means | What to do |
|---|---|---|
| 9Zeversolar error code 9 | Earth fault detector failure[1] The circuit that watches for current leaking to earth has itself failed its test. The inverter will not run without it, and it is an internal fault. Safe steps in the lookup |
Stop and call |
| 36Zeversolar error code 36 | Residual current (earth) fault[1] The inverter detected current leaking to earth above its limit. That usually means a wet or damaged part of the DC side, and the unit stops until it is fixed. Safe steps in the lookup |
Stop and call |
| 38Zeversolar error code 38 | Insulation (ISO) fault[2] The inverter measured too little insulation between the solar array and earth, or the insulation inside the inverter has failed. Water in a roof connector, a damaged cable or an internal fault are the usual causes, and the unit stops until it is cleared. Safe steps in the lookup |
Stop and call |
| 43Zeversolar error code 43 | Internal earth current mismatch[1] The inverter's two processors measured different earth leakage currents. One restart after three minutes off sometimes clears it; if it returns the control board is failing. Anything to do with earth or leakage current is a safety fault, so we treat it as a call. Safe steps in the lookup |
Stop and call |
The unit's own electronics: relays, sensors, the DC bus, memory and its self-checks. Nearly all of these need an electrician. 13 stop and call.
| Error code | What it means | What to do |
|---|---|---|
| 1Zeversolar error code 1 | Internal communication fault[1] The two processors inside the inverter have stopped talking to each other. The manual calls this a permanent fault: an internal board problem, not something outside the unit. Safe steps in the lookup |
Stop and call |
| 2Zeversolar error code 2 | Memory read or write fault[1] The inverter could not read or write its settings memory. One safe restart sometimes clears it; if it comes back the control board is failing. Internal and hardware faults need testing with the right instruments, so we treat them as a call. Safe steps in the lookup |
Stop and call |
| 3Zeversolar error code 3 | Output relay failure[2] The relay that connects the inverter to the grid has failed its self-test. This is an internal hardware fault, and on a Zeversolar it cannot be repaired. Safe steps in the lookup |
Stop and call |
| 4Zeversolar error code 4 | DC injection too high[1] The inverter is pushing too much direct current into the grid, which the rules do not allow. The manual lists it as a permanent fault that needs a restart and then service if it returns. DC on the AC side is a protection fault, so we treat it as a call. Safe steps in the lookup |
Stop and call |
| 6Zeversolar error code 6 | DC bus voltage too high[1] The voltage on the inverter's internal DC bus went above its limit. If the string voltage is within range, the manual says the internal circuit has broken. Safe steps in the lookup |
Stop and call |
| 8Zeversolar error code 8 | Output current sensor fault[1] The sensor that measures the inverter's output current is reading wrong. It is an internal hardware fault listed as permanent in the manual. Safe steps in the lookup |
Stop and call |
| 10Zeversolar error code 10 | Device fault, unknown error[1] The inverter has stopped on an internal fault it cannot name. The manual gives no fix for this code, so treat it as a hardware failure. Safe steps in the lookup |
Stop and call |
| 41Zeversolar error code 41 | Internal voltage reading mismatch[1] The inverter's two processors measured different grid voltages. One restart after three minutes off sometimes clears it; if it returns the control board is failing. Internal and hardware faults need testing with the right instruments, so we treat them as a call. Safe steps in the lookup |
Stop and call |
| 42Zeversolar error code 42 | Internal frequency reading mismatch[1] The inverter's two processors measured different grid frequencies. One restart after three minutes off sometimes clears it; if it returns the control board is failing. Internal and hardware faults need testing with the right instruments, so we treat them as a call. Safe steps in the lookup |
Stop and call |
| 44Zeversolar error code 44 | Internal DC injection mismatch[1] The inverter's two processors measured different DC injection values. One restart after three minutes off sometimes clears it; if it returns the control board is failing. DC on the AC side is a protection fault, so we treat it as a call. Safe steps in the lookup |
Stop and call |
| 45Zeversolar error code 45 | Internal grid reading mismatch[1] The inverter's two processors measured different grid frequency and voltage values. One restart after three minutes off sometimes clears it; if it returns the control board is failing. Internal and hardware faults need testing with the right instruments, so we treat them as a call. Safe steps in the lookup |
Stop and call |
| 47Zeversolar error code 47 | Internal consistency fault[3] The inverter's two processors disagree on a reading (Zeverlution models). One restart sometimes clears it; if it returns the control board is failing. Internal and hardware faults need testing with the right instruments, so we treat them as a call. Safe steps in the lookup |
Stop and call |
| 40Zeversolar error code 40 | Inverter over temperature[1] The inside of the inverter got too hot, so it cut back or stopped. Blocked airflow around the heat sink or a hot spot in full sun is the usual cause. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call. Safe steps in the lookup |
Stop and call |
Monitoring, Wi-Fi, meters, communication between parts of the system, settings and firmware. Usually not a hardware fault, but the system may stop reporting. 1 stop and call, 2 wait and watch.
| Error code | What it means | What to do |
|---|---|---|
| 11Zeversolar error code 11 | Firmware version mismatch[7] The two processors inside the inverter are running different firmware versions. This only appears after a failed update or a board fault and cannot be fixed from outside. Best effort · from a secondary copySafe steps in the lookup |
Stop and call |
| 61Zeversolar error code 61 | DRED communication fault[3] The demand response (DRED) input has lost its connection or its link is open (Zeverlution S1 models). It is a communications warning rather than a power fault. Safe steps in the lookup |
Wait and watch |
| Monitoring not workingZeversolar Monitoring not working | ZeverCloud monitoring is gone[6] Zeversolar stopped trading in December 2019 and its ZeverCloud monitoring servers went off in 2021, so the app and portal will never reconnect. The inverter itself can still be working fine: read its screen or your electricity bill instead. Best effort · from a secondary copySafe steps in the lookup |
Wait and watch |
No Zeversolar error code matches that. Try the fault code lookup, which also works from a description of what you can see.
Our own licensed electricians cover Greater Adelaide and regional SA, and from North Brisbane up through the Sunshine Coast to Gympie. Check your postcode, then read us the code and tell us the install year. If it needs a visit, the callout is credited against the work.
Try one restart, in this order:
Never open the unit or touch the wiring. Never restart anything that smells hot or shows scorch marks. If the code comes back after one restart, stop and call.
Before anyone blames the inverter, our electricians test the whole system: insulation resistance on each string, earth continuity, the output relay, DC string voltages and currents, the AC supply and whatever the unit has logged. Error 38 shows why. The manual puts it down to low insulation between the array and earth, which is often water in a roof connector or a damaged cable and gets fixed on the roof. It can also be the inverter's own insulation, and testing tells you which.
Error 3, an output relay that has failed its self-test, is the opposite case: it is inside the unit, and on a Zeversolar it cannot be repaired. For faults like that we quote a straight replacement and a hybrid option side by side, so you can add a battery now or later. Your panels usually stay, and the callout comes off whichever you choose.
We do this work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland only. Outside those areas, everything above still applies: take the code, its meaning and the urgency to a licensed electrician near you.
Every Zeversolar code on this page was read from the maker's own manual wherever one survives (85 per cent of them). Where only a secondary copy survives, the row says "best effort" and so does the lookup. The numbers match the references in the code table.
Tables last updated
Look at the screen in daylight, when the inverter is awake, and note the number and whether it clears after a few minutes. Roughly, 33 to 35 and 48 are the grid, 36 to 38 the panels and earth, 40 is heat, and most of the rest are faults inside the unit. Type the number into the search box above the table.
38 is “insulation (iso) fault”. The inverter measured too little insulation between the solar array and earth, or the insulation inside the inverter has failed. Water in a roof connector, a damaged cable or an internal fault are the usual causes, and the unit stops until it is cleared. We rate it stop and call. See it in the table.
3 is “output relay failure”. The relay that connects the inverter to the grid has failed its self-test. This is an internal hardware fault, and on a Zeversolar it cannot be repaired. We rate it stop and call. See it in the table.
We work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland. Check your postcode to be sure. Outside those areas, this page still tells you what your code means and how urgent it is, and a licensed electrician near you can take it from there.
For homes in our service area, the phone diagnosis is free. If it needs a visit, there is a callout fee, and it is credited against any repair or replacement we do.
Yes, if it is in our service area. Most of our repair work is on systems someone else installed. We test the whole system, not just the unit on the wall.
Because the service is gone. Zeversolar ceased business in December 2019 and ZeverCloud was switched off in late 2021, so a quiet app is normal and not a fault in your inverter. Check the screen in daylight for a Normal state and a power reading. If you want monitoring back, a visit can fit a third-party energy monitor at the switchboard.
For a fault inside the inverter, usually not, because there are no parts and no warranty. For a fault outside it, like water in a roof connector or a tripped switch, yes, and that is why we test first. We tell you which on the phone where we can, and price the replacement beside any repair that still makes sense.
Most come from Zeversolar’s own installation and operating instructions for the Eversol TL range and the Zeverlution S1. Four rows rely on secondary copies because no maker’s manual covers them: code 11, code 48, the dead screen and ZeverCloud. Those say best effort, and every code carries a numbered reference to its document in the source list.
More solar repairs guides from our electricians.
Swipe to see more

All 17 Samil Power error codes in plain English, from Isolation Fault to Relay Failure: what each message means, how urgent it is, how to restart safely, and what your replacement options are with no Samil support left in Australia.
Read more
All 12 Aerosharp error messages we could trace, in plain English: what each one means, how urgent it is, how to restart safely, and what to replace the inverter with now the maker is long gone.
Read more$0 power bill guarantee
If you are considering solar for a new home, or on behalf of someone else, select "I own my home"
A solar or battery system is a permanent change to the property, so it needs to be arranged by the person who owns the home.
If you tapped that by mistake, head back and we'll pick up where you left off.
Our team can talk you through all options if you're not sure.
You'll get all of these. We'd just like to know what matters most.
The average Adelaide home spends $500 - $1000 per quarter. Not sure of yours? Take your best guess, we'll go through the real numbers at your assessment.
Whatever it is today, our goal is $0. If we don't get you there, we'll pay your bill.
We can work with you on a longer timeline, or get you saving as soon as possible.
We have hundreds of happy customers across South Australia. We need your address to check we service your area and to look at your roof before we visit.
Great news, we service your area!
Every system we design is tailored to the home, so the more info the better! (Optional)
Last step. We'll call to arrange your free on-site assessment at a time that suits you. No pressure and no obligation.
Request sent, we'll be in touch!
Call to speak directly with a solar specialist during business hours, and we can get your free on-site assessment booked in straight away.
📞If you haven't called already, we'll give you a call to say hello.
We'll chat about what you're looking for, how we can help, and book in a time for your on-site assessment that suits you.
We visit your home for 45 to 60 minutes to measure up the roof, check the switchboard and review how you use power.
A tailored proposal with the system design, the savings and the pricing laid out in full.
If you're happy with the proposal, our in-house team installs it and shows you how it all works.