The Complete Guide To SolarEdge Inverter Error Codes

All 40 SolarEdge error codes in plain English, from the old numbered errors to codes like 2x19 and 18x86, plus the optimiser messages: what each one means, how urgent it is, how to restart the system safely, and whether it can be repaired.

Jump to the 40 SolarEdge error codes

Why a SolarEdge error code is worth sorting now

A SolarEdge showing an error code, or a monitoring app with panels missing, means some or all of your solar is not reaching the house. Whatever it is not making, you buy from the grid at full price. A few SolarEdge codes are safety faults: an isolation fault means DC is leaking to earth somewhere on the roof, and an arc fault is a fire risk.

SolarEdge is supported in Australia, and it is built differently from most inverters: optimisers on the roof report to the inverter on the wall, and the monitoring shows each panel's output. So a fault is often in one optimiser rather than the inverter, which changes what the visit looks like. Plenty of codes are simpler again: a grid voltage trip, a lock-out that needs one restart, or the monitoring losing its wifi.

Found early, an optimiser or connector fault is usually one trip onto the roof while the rest of the system keeps working. Left alone, a missing optimiser keeps costing you that panel's output every day, and a leak to earth can lock the whole system out.

Find your code in the table below to see what it means and how urgent it is. If your home is in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland, our own licensed electricians will go through it with you over the phone for free before anyone drives out. Check your postcode to see if we cover you.

Which SolarEdge inverter do you have?

The model is on the label on the side of the inverter. The SolarEdge monitoring app shows the system's status and each panel's output, which helps when a code points to the roof.

  • HD-Wave single-phase: SolarEdge's single-phase inverters with HD-Wave technology. Many of the 18x codes on this page, such as 18x3D and 18xA6, come from these. Supported.
  • SetApp inverters: newer units the installer sets up with SolarEdge's SetApp. On these an isolation fault shows as 18x86. Supported.
  • Older single-phase inverters: units on firmware 3.18 and earlier, which show plain numbers such as Error 8 and Error 18. Whether one is worth repairing depends on the fault.
  • Power optimisers: the units on the roof that report each panel's output to the inverter. Many SolarEdge faults turn out to be one optimiser rather than the inverter.

All 40 SolarEdge error codes, explained

SolarEdge shows a fault on the inverter's screen and in the monitoring as a short code: a number, an x, then a number or letter, like 2x19 or 18x86. Older units on firmware 3.18 and earlier show plain numbers instead, and the status screen also shows messages such as Night Mode and the optimiser count. Every code is below, grouped by what it relates to: the grid and mains supply, the panel input and power output, insulation and earth faults, heat and cooling fans, the unit's internal hardware, and monitoring. The number in brackets after each code's name is its source in the reference list.

  • Stop and call A safety or hardware fault that nobody can fix from a phone. Do the one safe restart at most, then call.
  • Worth a look Something to check or restart safely. If it comes back, book a visit.
  • Wait and watch The inverter has paused for a reason outside itself, usually the grid or the light, and restarts on its own.

We always err on the cautious side: when a code sits between two ratings, it gets the higher one.

Grid and mains supply error codes 11 codes

The mains grid coming into the unit: voltage, frequency and outages. Many of these are the grid, not the inverter, and clear on their own. 1 stop and call, 2 worth a look, 8 wait and watch.

Error codeWhat it meansWhat to do
Error 2x1DSolarEdge Error 2x1D Active to neutral voltage out of range[1]

The voltage between active and neutral at the inverter went above or below the limit, so it disconnected. It reconnects itself; if it repeats, the AC connections and the grid supply need checking.

Safe steps in the lookup
Wait and watch
Error 2x1FSolarEdge Error 2x1F Grid voltage too high[1]

The grid voltage at the inverter is above the Australian limit, so it disconnected to protect the grid. It reconnects itself when the voltage drops; it is common on sunny afternoons in streets with a lot of solar, and if it repeats daily the cable run or the network needs looking at.

Safe steps in the lookup
Wait and watch
Error 2x9SolarEdge Error 2x9 Current surge on the AC side[1]

The inverter saw a sudden surge in ground current or AC current, which usually comes from the grid side, such as a nearby large load switching or a network event. SolarEdge says to check the AC connection and ask the network about surge sources; if the grid is fine and it keeps happening, support needs to look at the inverter. Anything to do with earth or leakage current is a safety fault, so we treat it as a call.

Safe steps in the lookup
Stop and call
Error 2x20SolarEdge Error 2x20 Grid voltage too low[1]

The grid voltage at the inverter dropped below the limit, so it disconnected. This is usually a dip on the network, a blackout or a tripped solar breaker, and the inverter reconnects itself when the voltage returns.

Safe steps in the lookup
Wait and watch
Error 2x22SolarEdge Error 2x22 Grid frequency out of range[3]

The grid frequency went above or below the allowed band, so the inverter disconnected. This comes from the network, not your system, and the inverter reconnects itself when the frequency is back in range.

Safe steps in the lookup
Wait and watch
Error 2xESolarEdge Error 2xE AC voltage surge[1]

The grid voltage spiked above the inverter's limit for a moment and it disconnected to protect itself. One-offs are normal; if it keeps happening the AC cable may be undersized for the run or the street voltage is high.

Safe steps in the lookup
Wait and watch
Error 3x60SolarEdge Error 3x60 Unconfirmed code, lock-out family[1]

SolarEdge's published lists have no code 3x60. Its 3x codes are communication and lock-out conditions (the inverter locked itself and needs an OFF/ON to reconnect), and the similar-looking 18x60 means the grid is down and the inverter restarts itself when power returns. Note the exact code and description on the screen; one restart is safe, and if it returns an installer needs to read the log.

Best effort · from a secondary copySafe steps in the lookup
Worth a look
Error 3xBSolarEdge Error 3xB No country selected[1]

The inverter has no grid country setting, or the wrong one, so it will not connect. Nothing is broken; the installer selects the Australian setting through SetApp or the LCD.

Safe steps in the lookup
Worth a look
Error 18x37SolarEdge Error 18x37 Grid voltage out of range[4]

On HD-Wave inverters 18x37 and 18x38 are the grid voltage trips, one for too low and one for too high. The inverter disconnects to protect the grid and reconnects itself when the voltage settles; if it repeats most days the cable run or the network supply needs checking.

Safe steps in the lookup
Wait and watch
Error 18x40SolarEdge Error 18x40 Grid frequency out of range[1]

The 18x40 to 18x5D codes on HD-Wave inverters all mean the grid frequency measured on a phase was higher or lower than the allowed band. It is a network condition; the inverter reconnects itself, and SolarEdge's only on-site steps are to confirm the country code and the grid frequency.

Safe steps in the lookup
Wait and watch
Error 18x60SolarEdge Error 18x60 Grid is down[1]

The inverter has lost the grid, either a blackout, a tripped solar breaker or an islanding trip where it detected it was alone on the line. It restarts itself after the reconnection time once the grid is back; nothing is wrong with the inverter.

Safe steps in the lookup
Wait and watch

Panel input and power output error codes 3 codes

The DC input from the panels and the power the unit puts out: string voltage, low light, overloads and output limits. 2 worth a look, 1 wait and watch.

Error codeWhat it meansWhat to do
Error 2xFSolarEdge Error 2xF DC voltage too high[1]

The DC voltage into the inverter went above its limit. The optimisers normally stop this, so if it persists a string or optimiser is misbehaving and SolarEdge's steps involve isolating strings, which is a job for an electrician.

Safe steps in the lookup
Worth a look
Night ModeSolarEdge Night Mode Night mode, no DC[1]

The inverter is in night mode because it is getting less than 6 volts from the panels, which is normal after dark and before sunrise. If it shows in the middle of a clear day, the DC side is not delivering and needs testing.

Safe steps in the lookup
Wait and watch
Pairing failedSolarEdge Pairing failed Optimiser pairing failed[6]

The inverter could not pair with all of its optimisers. SolarEdge's first cause is shade on the panels during pairing, and the others are a disconnected or faulty optimiser, so if a retry in full sun does not work the installer needs to check the string.

Safe steps in the lookup
Worth a look

Panels, insulation and earth faults error codes 8 codes

Insulation, earth and leakage faults on the solar panel side. These are safety faults: live DC wiring may be leaking to earth somewhere on the roof. 8 stop and call.

Error codeWhat it meansWhat to do
Error 2x1CSolarEdge Error 2x1C RCD sensor error[13]

The sensor that watches for current leaking to earth has failed inside the inverter, so it cannot protect the system and has stopped. This is an internal fault for SolarEdge support, not a panel problem.

Safe steps in the lookup
Stop and call
Error 2x19SolarEdge Error 2x19 Isolation fault[5]

Every time it starts, the inverter checks the insulation between the solar DC wiring and earth, and it found less than 600 kilo-ohms. That means DC is leaking to earth somewhere, usually moisture in a connector or optimiser, a damaged cable or a faulty panel. It is a safety trip: do not keep resetting it, the string has to be tested and the leak found.

Safe steps in the lookup
Stop and call
Error 2x98SolarEdge Error 2x98 Arc detector self-test failed[7]

The inverter's arc fault detector could not pass its own test, so it cannot protect the DC wiring from arcing. SolarEdge points to its arc detection application note; an installer needs to check the detector and the DC side. A failed self-test means the inverter cannot prove its own protection works, so we treat it as a call.

Safe steps in the lookup
Stop and call
Error 2xASolarEdge Error 2xA Ground current, RCD trip[10]

The inverter's residual current protection tripped because current is leaking from the solar wiring to earth, which means the insulation to earth is not good enough somewhere. SolarEdge says only a qualified technician should handle this, connecting one string at a time to find the faulty one.

Safe steps in the lookup
Stop and call
Error 3x9ASolarEdge Error 3x9A Inverter locked, restart needed[1]

SolarEdge's current error list says 3x9A means the inverter has locked itself, either because someone switched it off or because one of its safety features tripped, and it needs an OFF/ON to reconnect. Some trade websites call 3x9A an isolation fault, but that is not what SolarEdge publishes; if a restart does not clear it, an installer has to find out from the log why it locked. Insulation faults are a safety fault, so we treat them as a call.

Safe steps in the lookup
Stop and call
Error 18x3DSolarEdge Error 18x3D Ground current, RCD trip[2]

On HD-Wave inverters 18x3D and 18x3E are the residual current trips: current is leaking from the solar wiring to earth faster or further than allowed. SolarEdge's instruction is to contact support, and the DC side needs testing before anyone resets it.

Safe steps in the lookup
Stop and call
Error 18x86SolarEdge Error 18x86 Isolation fault[5]

On SetApp inverters 18x86 is the isolation fault: the inverter measured less than 600 kilo-ohms between the solar DC wiring and earth, so DC is leaking to earth, usually from moisture in a connector or optimiser, a damaged cable or a faulty panel. It often comes and goes with morning dew, which is why it should be tested while it is showing rather than reset.

Safe steps in the lookup
Stop and call
Error 18xCSolarEdge Error 18xC Arc fault detected[8]

The inverter detected an electrical arc in the solar DC wiring, which is a fire risk, and has shut down. Do not reset it; the DC connectors, optimiser leads and cables need to be inspected and tested first.

Safe steps in the lookup
Stop and call

Heat and cooling fans error codes 4 codes

Over-temperature, heat derating and the cooling fans. Heat faults are taken seriously: a unit that cannot cool itself can be a fire risk. 4 stop and call.

Error codeWhat it meansWhat to do
Error 2x11SolarEdge Error 2x11 Inverter too hot[1]

The inverter has shut down because it is too hot. SolarEdge says to check the clearances around it and that the heat-sink fins are clean, but an inverter that keeps overheating usually has a cooling or mounting problem that needs a technician.

Safe steps in the lookup
Stop and call
Error 2x18SolarEdge Error 2x18 Temperature sensor fault[1]

The inverter's internal temperature sensor is broken or disconnected, so it cannot protect itself from overheating. SolarEdge's instruction is to contact support; it is an internal fault for a technician.

Safe steps in the lookup
Stop and call
Error 18x75SolarEdge Error 18x75 Thermal shutdown[9]

Trade guides list 18x75 as the HD-Wave inverter shutting down because it is too hot; it does not appear in SolarEdge's own published error lists. An inverter that overheats more than once has a cooling or mounting problem that needs a technician. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call.

Best effort · from a secondary copySafe steps in the lookup
Stop and call
Warning 1SolarEdge Warning 1 Fan failure[1]

A cooling fan in the inverter has failed. It usually keeps producing but will run hot and may start cutting its output, so the fan should be cleaned or replaced by a technician before summer. A fan fault lets the inverter overheat, so we treat it as a call.

Safe steps in the lookup
Stop and call

Internal hardware and safety checks error codes 7 codes

The unit's own electronics: relays, sensors, the DC bus, memory and its self-checks. Nearly all of these need an electrician. 7 stop and call.

Error codeWhat it meansWhat to do
Error 2x1ASolarEdge Error 2x1A Faulty AC relay[7]

The relay that connects the inverter to the grid has failed its check, so the inverter cannot safely connect. This is an internal fault; SolarEdge's instruction is to contact support.

Safe steps in the lookup
Stop and call
Error 2x10SolarEdge Error 2x10 Hardware error[1]

The inverter has found a fault in its own hardware, such as its internal voltage reference or power stage, and stopped. SolarEdge's instruction is to contact support for a warranty claim, so it needs a technician to log it; it is not a panel or wiring problem.

Safe steps in the lookup
Stop and call
Error 3x1ASolarEdge Error 3x1A Unconfirmed code, grid or relay[12]

SolarEdge's published lists have no single-phase code 3x1A. The closest documented codes are 2x1A (a faulty AC relay inside the inverter, a technician job) and 33x1A (an AC voltage surge on a commercial inverter); one trade website calls 3x1A grid voltage out of range. Note the exact code and the description under it on the screen, and if it keeps coming back have an electrician check it. A relay fault can leave the inverter unable to disconnect safely, so we treat it as a call.

Best effort · from a secondary copySafe steps in the lookup
Stop and call
Error 3x2SolarEdge Error 3x2 Internal software or comms error[4]

The inverter's main controller has lost contact with its internal digital board or hit a software error. SolarEdge's instruction is to contact support; it needs a technician to log it and check whether a firmware upgrade or replacement is needed.

Safe steps in the lookup
Stop and call
Error 3x6ASolarEdge Error 3x6A Inverter locked, restart to reconnect[1]

The inverter has locked itself out, either because someone switched it off or because a safety feature tripped, and it needs an OFF/ON to reconnect. SolarEdge says the installer needs to know why it locked in the first place, so if it happens again after a restart, book a visit. A protection lockout means the inverter found something it will not run with, so we treat it as a call.

Safe steps in the lookup
Stop and call
Error 18xA6SolarEdge Error 18xA6 Hardware error[2]

On HD-Wave inverters the 18xA6 to 18xAB codes are hardware errors, including an overvoltage on the DC input. SolarEdge's instruction is to check the string voltage and contact support, so it needs a technician.

Safe steps in the lookup
Stop and call
Error 18xB5SolarEdge Error 18xB5 Internal overvoltage, hardware fault[1]

The inverter has measured an overvoltage inside its own power stage, which on HD-Wave units points to a failed internal component. SolarEdge lists it as a warranty (RMA) matter: contact support, so it needs a technician to log the serial number; it is not a panel or grid problem.

Safe steps in the lookup
Stop and call

Monitoring, communication and settings error codes 7 codes

Monitoring, Wi-Fi, meters, communication between parts of the system, settings and firmware. Usually not a hardware fault, but the system may stop reporting. 4 stop and call, 3 worth a look.

Error codeWhat it meansWhat to do
Error 3x6SolarEdge Error 3x6 Inverter locked or meter fault[11]

SolarEdge publishes no code that is just 3x6. The codes that start this way are 3x6A (the inverter locked itself, by a switch-off or a safety feature, and needs an OFF/ON to reconnect), 3x6D (an error in the built-in energy meter) and 3x6E (the inverter cannot talk to its meter). None is a wiring hazard, but if a restart does not clear it an installer has to find out why it locked. A protection lockout means the inverter found something it will not run with, so we treat it as a call.

Best effort · from a secondary copySafe steps in the lookup
Stop and call
Error 3x6ESolarEdge Error 3x6E Energy meter not communicating[2]

The inverter cannot talk to its energy meter (3x6E), or the built-in meter has an internal error (3x6D). Solar production is not affected, but export limiting and consumption data may be wrong until the meter wiring or settings are fixed. Internal and hardware faults need testing with the right instruments, so we treat them as a call.

Safe steps in the lookup
Stop and call
Error 3x14SolarEdge Error 3x14 Inverter communication lock-out[1]

SolarEdge's published error lists have no code 3x14; the 3x family covers communication and lock-out conditions, and the nearest listed code, 3x114, means the inverter has locked itself and needs an OFF/ON to reconnect. Treat it as a lock-out: one restart is safe, and if it returns an installer needs to read the log.

Best effort · from a secondary copySafe steps in the lookup
Worth a look
Error 8SolarEdge Error 8 Software error[3]

On older single-phase SolarEdge inverters (firmware 3.18 and earlier) error numbers 4, 5, 8, 18 to 23, 39, 42, 45 and 48 are all the same thing: a software or internal fault, and SolarEdge's only instruction is to contact support. It needs a technician to log the serial number and error with SolarEdge; it is not a grid or panel problem.

Safe steps in the lookup
Stop and call
Error 18SolarEdge Error 18 Software error[3]

Error 18 (and 19 to 23) on the older single-phase inverters is a software or internal fault; on newer firmware the same fault shows as 2x13, 2x15, 2x16 or 2x2D. SolarEdge's instruction is to contact support, so it needs a technician rather than a reset.

Safe steps in the lookup
Stop and call
No communicationSolarEdge No communication Monitoring not connected[2]

The inverter cannot reach the SolarEdge monitoring server, so the app shows it offline and S_OK is missing from the status screen. Production is usually fine; it is almost always the home wifi or router, a changed password or an unplugged cable.

Safe steps in the lookup
Worth a look
Optimiser not reportingSolarEdge Optimiser not reporting Optimiser not reporting[6]

The inverter status shows fewer optimisers reporting than are installed (P_OK with x less than y), or the monitoring shows a panel with no data. One optimiser missing around dawn or dusk is usually shade; one missing all day, or several at once, means an optimiser, its connector or its panel has a fault, and that is a roof job.

Safe steps in the lookup
Worth a look

Got a SolarEdge error code? Free phone diagnosis in our service area

Our own licensed electricians cover Greater Adelaide and regional SA, and from North Brisbane up through the Sunshine Coast to Gympie. Check your postcode, then read us the code and tell us the install year. If it needs a visit, the callout is credited against the work.

How to reset a SolarEdge inverter safely

A SolarEdge inverter has its own ON/OFF switch as well as the DC isolator, so the restart has one extra step. Try it once, in this order:

  1. Switch the solar supply main switch off at the switchboard.
  2. Switch the inverter's ON/OFF switch and the DC isolator off.
  3. Wait five minutes.
  4. Switch the DC isolator and the inverter's ON/OFF switch back on, then the solar supply main switch.

Never open the unit or touch the wiring, and stay off the roof: the optimisers are a job for an electrician. Never restart anything that smells hot or shows scorch marks. If the code comes back after one restart, stop and call.

SolarEdge inverter repair or replacement?

On a visit, our electricians test the whole system before they blame the inverter, and with SolarEdge that includes the optimisers. That means insulation resistance on every string, earth continuity, the relay, DC string voltages and currents, what each optimiser is reporting, the AC supply and the inverter's own log. An isolation fault such as 2x19 or 18x86 is often moisture in one connector or optimiser, and the fix is on the roof, not in the inverter.

SolarEdge is supported in Australia, so a failed optimiser or an internal inverter fault can often be put right with a part rather than a whole new system. Several SolarEdge codes are logged with SolarEdge for a warranty claim, so if the inverter is still under warranty, we check that first. If a replacement does make more sense, we quote a straight replacement and a hybrid option side by side, and the callout comes off whichever you choose.

We do this work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland only. Outside those areas, everything above still applies: take the code, its meaning and the urgency to a licensed electrician near you.

Where these SolarEdge error codes come from

Every SolarEdge code on this page was read from the maker's own manual wherever one survives (88 per cent of them). Where only a secondary copy survives, the row says "best effort" and so does the lookup. The numbers match the references in the code table.

  1. [1]
  2. [2]
  3. [3]
    Troubleshooting SolarEdge Systems, Addendum (Europe and APAC) MAN-01-00333-1.13 codes, from the maker's own document
  4. [4]
  5. [5]
  6. [6]
  7. [7]
    Troubleshooting SolarEdge Systems, Addendum (Europe and APAC) MAN-01-00333-1.1 and User Guide v1.22 codes, from the maker's own document
  8. [8]
  9. [9]
    Solar Permit Solutions, SolarEdge Inverter Error Codes: Complete Troubleshooting Guide (6 February 2026)1 code, best effort, from a secondary copy
  10. [10]
  11. [11]
  12. [12]
  13. [13]
    Troubleshooting SolarEdge Systems, Addendum (Europe and APAC) MAN-01-00333-1.1 and HD-Wave Appendix A MAN-01-250-1.21 code, from the maker's own document

Tables last updated

SolarEdge error code questions, answered

How do I read a SolarEdge error code?

Copy the code exactly, including the x and any letter after it: 3x6A and 3x6E are different faults. If your inverter shows a plain number such as 8 or 18, it is an older unit on firmware 3.18 or earlier. Search the code, or a word like optimiser or isolation, in the table above.

What does SolarEdge Error 3x9A mean?

Error 3x9A is “inverter locked, restart needed”. SolarEdge’s current error list says 3x9A means the inverter has locked itself, either because someone switched it off or because one of its safety features tripped, and it needs an OFF/ON to reconnect. Some trade websites call 3x9A an isolation fault, but that is not what SolarEdge publishes; if a restart does not clear it, an installer has to find out from the log why it locked. Insulation faults are a safety fault, so we treat them as a call. We rate it stop and call. See it in the table.

What does SolarEdge Error 18 mean?

Error 18 is “software error”. Error 18 (and 19 to 23) on the older single-phase inverters is a software or internal fault; on newer firmware the same fault shows as 2×13, 2×15, 2×16 or 2x2D. SolarEdge’s instruction is to contact support, so it needs a technician rather than a reset. We rate it stop and call. See it in the table.

Do you cover my area?

We work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland. Check your postcode to be sure. Outside those areas, this page still tells you what your code means and how urgent it is, and a licensed electrician near you can take it from there.

What does it cost to have a SolarEdge looked at?

For homes in our service area, the phone diagnosis is free. If it needs a visit, there is a callout fee, and it is credited against any repair or replacement we do.

Will you work on a SolarEdge you did not install?

Yes, if it is in our service area. Most of our repair work is on systems someone else installed. We test the whole system, not just the unit on the wall.

Why does my SolarEdge app say a panel or optimiser is not reporting?

One optimiser missing around dawn or dusk is usually shade, and it comes back with the sun. One missing all day, or several at once, means an optimiser, its connector or its panel has a fault. Wait for a full-sun day and check again. If it is still missing, book an electrician and stay off the roof.

My SolarEdge code is on other websites but not in SolarEdge’s list. Which is right?

We go with SolarEdge’s own lists. Some codes people search for, like 3×6, 3×14, 3×60 and 3x1A, are not in SolarEdge’s published lists, and trade websites give them different meanings. For those, the table gives the closest code SolarEdge does publish and marks the row best effort. An electrician reading the inverter’s log will confirm which it is.

Where do the codes on this page come from?

Mostly from SolarEdge’s own documents: its error code user guide, the HD-Wave installation guide, its troubleshooting addendum for Europe and APAC, and its isolation fault application note. A few rows rest on a secondary copy or are the closest match to a code SolarEdge does not publish, and those say best effort. Each code carries a numbered reference to its document in the source list.