The Complete Guide To Hoymiles Microinverter Error Codes

All 29 Hoymiles microinverter alarms, DTU messages and lights in plain English: what each one means, how urgent it is, how to reset your system safely, and whether a faulty micro can still be fixed.

Jump to the 29 Hoymiles error codes

Why a Hoymiles error code is worth sorting now

A Hoymiles alarm in the S-Miles app usually means some of your panels have stopped making power, or the app has lost track of them. Panels sitting idle are power you buy back from the grid at full price. A few alarms are wiring faults, like 213 on the DC side or 221 on a three-phase system, where something was connected wrongly and needs an electrician before it runs again.

Hoymiles has been in Australia since 2022 through a Melbourne subsidiary, so these are newer systems on a supported brand. The micros sit under the panels, each taking more than one, and a DTU gateway passes their data to S-Miles Cloud. Many alarms are monitoring and reporting faults: the DTU offline, a serial number mix-up, a micro the DTU cannot hear. Others come from the grid, and the micros recover on their own. A micro with a real hardware fault cannot be repaired on site; it is swapped, and that is a roof job.

Caught early, it is usually one micro or one setting. Left alone, a port with nothing coming in or a micro that keeps dropping out costs you a panel or two of output every sunny day, and the app is easy to stop checking.

Find your code in the table below to see what it means and how urgent it is. If your home is in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland, our own licensed electricians will go through it with you over the phone for free before anyone drives out. Check your postcode to see if we cover you.

Which Hoymiles system do you have?

Hoymiles micros sit under the panels, and each one takes two or more panels on its own ports. The model is printed on each micro's label, and the S-Miles app shows the micros and their alarms on the plant page.

  • HM-600, HM-700 and HM-800: the earlier microinverters, covered by Hoymiles' 2020 manual.
  • HMS-600 to HMS-1000: single-phase microinverters from the 2022 manual. A solid red light on these means a hardware failure.
  • HMT-1800 and HMT-2250: three-phase microinverters. Alarms 171 and 221, both wiring faults, only show on these.
  • DTU-Pro and DTU-Pro-S: the DTU gateway, with four lights (RUN, Cloud, MI and ALM), that sends every micro's data to S-Miles Cloud.

All 29 Hoymiles error codes, explained

Hoymiles numbers its alarms in the S-Miles app, and several neighbouring numbers often share one row: the row's title says which, such as 141, 142. Plant messages like Offline, the DTU's lights and the light under each micro are listed by name. Every code is below, grouped by what it relates to: the grid and mains supply, the panel input and power output, monitoring, and anything else. The number in brackets after each code's name is its source in the reference list.

  • Stop and call A safety or hardware fault that nobody can fix from a phone. Do the one safe restart at most, then call.
  • Worth a look Something to check or restart safely. If it comes back, book a visit.
  • Wait and watch The inverter has paused for a reason outside itself, usually the grid or the light, and restarts on its own.

We always err on the cautious side: when a code sits between two ratings, it gets the higher one.

Grid and mains supply error codes 13 codes

The mains grid coming into the unit: voltage, frequency and outages. Many of these are the grid, not the inverter, and clear on their own. 3 stop and call, 1 worth a look, 9 wait and watch.

Error codeWhat it meansWhat to do
11Hoymiles error code 11 Grid transient (11 to 15)[8][10]

Short events the micro logs when the mains voltage spikes (11) or sags (12), or the frequency (13) or phase (14) jumps, with 15 a general transient. They come from the network and nothing is wrong with your system. The names come from the S-Miles installer app's alarm list as decoded by the open-source community, not a Hoymiles manual, so treat the wording as approximate. If production drops with them most days, an electrician can check.

Best effort · from a secondary copySafe steps in the lookup
Wait and watch
71Hoymiles error code 71 Output reduced by grid rules (71 to 73)[8][10]

Not faults. 71 means the micro is deliberately reducing output because the grid voltage is high (the volt-watt response Australian micros must apply under AS/NZS 4777.2), 72 because the frequency is high, and 73 because it is hot (around 80 degrees C), with full output back as it cools. The names come from the S-Miles installer app via the open-source community, not a manual. A 71 most afternoons is lost production worth chasing with the network.

Best effort · from a secondary copySafe steps in the lookup
Wait and watch
125Hoymiles error code 125 Grid profile setting error[1][2]

The grid profile (the country settings that tell the micro what voltage and frequency limits to use) is wrong or did not load properly. Hoymiles' fix is to check the grid configuration and send it again, which the installer does remotely from S-Miles Cloud; the micro may not produce until it is done. In Australia the profile should be the AS/NZS 4777.2 one for your network.

Safe steps in the lookup
Worth a look
141Hoymiles error code 141 Grid overvoltage (141, 142)[1][3][4]

The mains voltage at the micro went above the limit in its grid profile, so it stopped until it dropped back; 142 is the same measured as a 10-minute average, usually sustained high voltage on sunny afternoons. Hoymiles says an occasional one recovers by itself; if frequent, check the grid voltage with the power operator or have the limit adjusted with their consent. An electrician measures your own cable's voltage rise first.

Safe steps in the lookup
Wait and watch
143Hoymiles error code 143 Grid undervoltage[1][2]

The mains voltage at the micro dropped below the limit in its grid profile and it stopped until the voltage came back. Hoymiles says an occasional one recovers on its own; if it is frequent, check the grid voltage range with the power operator, and if the fault stays, check the AC switch and AC wiring. Every micro at once is the supply; one trunk or one micro is its breaker, connector or cable.

Safe steps in the lookup
Wait and watch
144Hoymiles error code 144 Grid frequency out of range (144 to 146)[1][3]

The mains frequency at the micro went above the limit (144), below it (145) or changed too quickly (146), and the micro paused until it was steady. This comes from the network, not your system; Hoymiles says an occasional one recovers by itself and a frequent one is for the power operator. A generator or changeover switch on the house supply can also cause it.

Safe steps in the lookup
Wait and watch
147Hoymiles error code 147 Grid outage or disconnection (147, 148)[1][3]

The micro cannot see the mains, so it has stopped, which is what it must do in a blackout. Hoymiles' notes are short: for 147 check whether there is a power outage; for 148 check the AC switch and AC wiring. The whole system showing it is a blackout or the solar breaker off; one trunk showing it is that trunk's breaker, end cable or a connector.

Safe steps in the lookup
Wait and watch
149Hoymiles error code 149 Island detected[1][3]

The micro's anti-islanding protection tripped: it decided the grid had gone or was too unstable to feed into and shut off, which is the safety behaviour the standard requires. Hoymiles says an occasional one recovers on its own; if it shows frequently on every micro, the power operator should check for an island on the supply, and if it persists, support.

Safe steps in the lookup
Wait and watch
171Hoymiles error code 171 Phase wiring wrong (three-phase)[5]

On the three-phase HMT micros, alarm 171 means the voltage difference between phases is abnormal, which Hoymiles says is usually caused by the phases being wired wrongly. It is an installation wiring fault at the AC trunk or switchboard, and the micro will not run properly until an electrician corrects it. It normally shows on every micro on that trunk.

Safe steps in the lookup
Stop and call
221Hoymiles error code 221 Grid neutral wiring wrong[5]

The three-phase HMT micro reports that its neutral is not properly connected to the grid neutral. Hoymiles says to confirm the micros' neutral lines are connected to the neutral of the grid correctly. It is a wiring fault at the AC trunk or switchboard that an electrician must fix before the micros can run safely; it normally shows on every micro on that trunk.

Safe steps in the lookup
Stop and call
Abnormal GridHoymiles Abnormal Grid Grid alarms across the system[7]

S-Miles Cloud flags the plant with Alarm or Grid Abnormality when more than half the micros report grid alarms at once (grid over voltage, under voltage or fluctuation). That comes from the supply, not the panels; the micros pause and come back on their own. If it shows most sunny afternoons the street voltage or your own cable run is high, which an electrician can measure and report.

Safe steps in the lookup
Wait and watch
Micro LED flashing red (0.5 s) or solid redHoymiles Micro LED flashing red (0.5 s) or solid red Micro fault, not the grid[1][2]

A fast red flash every half second means a fault other than the grid (the HMS manual says invalid AC grid or hardware failure), and a solid red light means a hardware failure. The exact alarm is on the platform. That micro is off and only its panel or panels are affected; it is a roof job and usually a warranty replacement, never something to touch yourself.

Safe steps in the lookup
Stop and call
Micro LED flashing red (1 s)Hoymiles Micro LED flashing red (1 s) No valid grid at the micro[1][2][11]

A red flash every second means the micro is not producing because the AC grid is invalid: voltage or frequency out of range, or no grid at all. Hoymiles' FAQ says a flashing red light may point to a grid voltage problem and to contact your installer. Every micro red is a blackout, a tripped solar breaker or the street voltage; one trunk red is its breaker, end cable or a connector.

Safe steps in the lookup
Wait and watch

Panel input and power output error codes 6 codes

The DC input from the panels and the power the unit puts out: string voltage, low light, overloads and output limits. 1 stop and call, 3 worth a look, 2 wait and watch.

Error codeWhat it meansWhat to do
205Hoymiles error code 205 Panel voltage too high (205, 206, 215)[1][3]

The panel on that input is putting out more voltage than the micro is rated for (65 V on the HM and HMS series), so the micro will not run it. Hoymiles' step is to make sure the panel's open-circuit voltage is at or below the maximum input; if it is, support looks at the micro. It usually means an unmatched panel was fitted and an electrician needs to check the pairing. Only that input is affected.

Safe steps in the lookup
Worth a look
207Hoymiles error code 207 Panel voltage too low (207, 208, 216)[1][3]

The voltage from the panel on that input is below the micro's operating range (the HM and HMS start at 22 V), so that input is not running. Every micro logging it at dawn, dusk or in heavy cloud is normal and it often appears at the end of each day. One input showing it in full sun while its neighbours run points to that panel, plug or lead, a roof job. The manual only says to check the panel voltage, then contact support.

Best effort · from a secondary copySafe steps in the lookup
Wait and watch
209Hoymiles error code 209 No panel input on a port (209 to 212, 217, 218)[1][3]

The micro sees nothing on that DC port. Hoymiles' steps are to confirm a panel is connected to the port and, if so, check the DC cable to the panel. A port never wired because the micro has more ports than panels is normal and the installer can mark it unused; a port that should have a panel points to an unplugged or damaged lead or a dead panel, which is a roof job.

Safe steps in the lookup
Worth a look
213Hoymiles error code 213 DC wiring wrong on a port pair (213, 214, 219)[5]

The panels on ports 1 and 2 (or 3 and 4, or 5 and 6) are wired to the micro incorrectly, for example the positive from one panel and the negative from another on the same port, or a reversed lead. Hoymiles' step is to check the DC connections on those two ports. It is an installation fault and an electrician has to correct it on the roof; only that micro is affected. Wiring faults need an electrician, so we treat them as a call.

Safe steps in the lookup
Stop and call
Micro LED fast green (1 s)Hoymiles Micro LED fast green (1 s) Normal, producing[1][2]

A green flash every second means the micro is producing power normally. Five quick green flashes when it first gets DC in the morning is a successful start-up. Nothing to do; if the app shows that panel offline, it is the data link to the DTU, not the micro.

Safe steps in the lookup
Wait and watch
Micro LED slow green (2 s)Hoymiles Micro LED slow green (2 s) Producing, one input abnormal[1][2]

A green flash every 2 seconds means the micro is producing but one of its DC inputs is abnormal: a panel, plug or lead on one port, or simply a port with no panel on it. The other panel or panels on that micro keep producing. If the port should have a working panel, checking it is a roof job.

Safe steps in the lookup
Worth a look

Monitoring, communication and settings error codes 8 codes

Monitoring, Wi-Fi, meters, communication between parts of the system, settings and firmware. Usually not a hardware fault, but the system may stop reporting. 1 stop and call, 6 worth a look, 1 wait and watch.

Error codeWhat it meansWhat to do
124Hoymiles error code 124 Shut down by remote control[6]

The micro has been switched off by a command, not by a fault: Hoymiles says to check the zero export (export limit) setting and whether the micros were shut down manually from the platform. Installers sometimes do this while a system waits for network approval. Ask whoever installed it; they can switch it back on remotely.

Safe steps in the lookup
Worth a look
126Hoymiles error code 126 Software error (126, 128, 129)[1][2]

Internal software errors inside the micro (129 is labelled 'Abnormal bias' on the HMS series). Hoymiles says that if one appears occasionally and the micro keeps working, no action is needed; if it keeps coming back or the micro does not recover, the dealer or Hoymiles support replaces it under warranty. Only that panel is affected. Internal and hardware faults need testing with the right instruments, so we treat them as a call.

Safe steps in the lookup
Stop and call
127Hoymiles error code 127 Firmware error[1][2]

The micro's firmware is wrong or corrupted; its light flashes red and green alternately. Hoymiles' fix is to check the firmware and upgrade it again, which the installer pushes through the DTU from S-Miles Cloud, after checking the DTU is talking to both the cloud and the micro. If the upgrade will not take, the micro is replaced under warranty. Only that panel is affected.

Safe steps in the lookup
Worth a look
130Hoymiles error code 130 Micro offline, not reporting[6][9][16]

Alarm 130 Offline means the DTU cannot hear from that micro while the DTU itself is online. Hoymiles' steps are to confirm the micro is working from its LED, that its serial number matches the platform, and that the radio link is good. One panel offline is usually range, a metal roof in the way or no daylight; every panel offline is the DTU or a serial number mix-up. Still offline after a day or two of sun is a roof job.

Safe steps in the lookup
Worth a look
DTU alarm lightHoymiles DTU alarm light DTU ALM light on[12][13][19]

The DTU-Pro and DTU-Pro-S have four lights: RUN, Cloud, MI and ALM. ALM means an alarm has been logged (DTU, micro or meter) and the platform's alarm page says which and gives Hoymiles' suggested fix. Cloud shows the internet state (disconnected, connected but not reaching the server, or communicating); MI shows whether the micros are talking and all serial numbers are loaded. Production is usually unaffected.

Safe steps in the lookup
Worth a look
Micro LED offHoymiles Micro LED off Micro not powered[4][15]

The micro is powered by its panels, so no light means no DC: at night, dawn, dusk or in heavy cloud that is normal. Hoymiles says if the light stays off to check the DC connection, and if that and the input voltage are normal, contact the dealer, meaning a failed micro. Five quick red flashes when DC is first connected means a failed start-up. In full sun either is a roof job.

Safe steps in the lookup
Wait and watch
OfflineHoymiles Offline DTU not connected to the internet[14][20][21]

S-Miles Cloud marks the whole plant Offline when the DTU gateway is not connected to the internet; the panels keep producing, the app just stops updating. Hoymiles' own checklist is the wifi password in the DTU, whether the wifi works, and weak signal. 'Network signal instability' is the milder version and 'Inactive' means no data for over half a year; both clear once the DTU is back online.

Safe steps in the lookup
Worth a look
SN does not matchHoymiles SN does not match Serial numbers do not match[7][9]

S-Miles Cloud raises this when a micro's serial number on the plant is wrong or already belongs to another plant, and every micro then shows offline. Hoymiles says it comes from the plant being created before the DTU wifi was set up, a serial number typed wrongly, or devices replaced, added or deleted. The installer fixes it remotely (DTU Networking) and the micros return within about 15 minutes.

Safe steps in the lookup
Worth a look

Other faults and alerts error codes 2 codes

Codes that do not fit the groups above. 2 stop and call.

Error codeWhat it meansWhat to do
121Hoymiles error code 121 Over temperature protection[1][4][17]

The micro has shut itself down because it is too hot and will start again once it cools. Hoymiles' steps are to check the ventilation and ambient temperature where it is mounted; it is meant to sit in the shade under the panel with clear space around it. One micro doing this on ordinary days when its neighbours do not usually has an airflow problem or is failing, and that is a roof job. Heat shutdowns point at a failing fan, a blocked vent or a bad installation spot, so we treat them as a call.

Safe steps in the lookup
Stop and call
301Hoymiles error code 301 Hardware error (301 to 309)[1][2][18]

An internal hardware fault inside that micro; on the HMS series the light goes solid red for a hardware failure. Hoymiles says a one-off that clears while the micro keeps producing needs no action, but one that repeats or does not recover goes to the dealer or Hoymiles support, which in practice means a warranty replacement. The micro cannot be repaired on site. Only that panel is affected.

Safe steps in the lookup
Stop and call

Got a Hoymiles error code? Free phone diagnosis in our service area

Our own licensed electricians cover Greater Adelaide and regional SA, and from North Brisbane up through the Sunshine Coast to Gympie. Check your postcode, then read us the code and tell us the install year. If it needs a visit, the callout is credited against the work.

How to reset Hoymiles microinverters safely

There is no DC isolator at the wall to switch on a microinverter system. A safe reset is mostly checks, in this order:

  1. Check the solar supply main switch and the solar breakers on the switchboard are on.
  2. Wait for full daylight and check the S-Miles app again. After a blackout the micros restart themselves a few minutes after good grid power returns.
  3. Check the DTU is plugged in and its lights are on, and that the internet works on another device in the house.
  4. Power the DTU off, wait one minute and power it on, and restart the router as well. Keep the DTU close to the panels and out of any metal box.
  5. Tap the alarm icon on the plant page for Hoymiles' suggested fix, then look the alarm number up in the table above.

Stay off the roof. Never open a micro or the DTU, and never touch the wiring. Never restart anything that smells hot or shows scorch marks. If the same panels stay offline after a day or two of sun, or an alarm stays on, stop and call.

Hoymiles microinverter repair or replacement?

On a visit, our electricians test the whole system first: the AC supply and the voltage rise on your own cable, each trunk's breaker and connectors, earth continuity, the DTU and its link to the micros, and the alarm history in S-Miles. Alarms like 213 (DC wiring wrong on a port pair) and 171 (phases wired wrongly on a three-phase HMT) are installation faults, and an electrician corrects them on the roof or at the switchboard.

Hoymiles is supported in Australia, and many alarms need no parts at all: a grid profile resent, firmware pushed, serial numbers fixed, often remotely by the installer. A micro with a hardware fault (301 to 309) cannot be repaired on site, so it is swapped. We tell you on the phone which kind of fault you have, and if it needs a visit, the callout comes off the work.

We do this work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland only. Outside those areas, everything above still applies: take the code, its meaning and the urgency to a licensed electrician near you.

Where these Hoymiles error codes come from

Every Hoymiles code on this page was read from the maker's own manual wherever one survives (90 per cent of them). Where only a secondary copy survives, the row says "best effort" and so does the lookup. The numbers match the references in the code table.

  1. [1]
    Hoymiles HM-600/700/800 Microinverter User Manual V1.0 (2020)17 codes, 16 of 17 from the maker's own document
  2. [2]
    Hoymiles HMS-600 to 1000-2T User Manual (2022), distributor copies9 codes, from the maker's own document
  3. [3]
    Hoymiles HMT-1800/2250 User Manual V1.0 (2020), distributor copies7 codes, 6 of 7 from the maker's own document
  4. [4]
    Hoymiles HMS-600 to 1000-2T User Manual (2022)3 codes, from the maker's own document
  5. [5]
    Hoymiles HMT-1800/2250 Three-phase Microinverter User Manual V1.0 (2020), distributor copy3 codes, from the maker's own document
  6. [6]
    Hoymiles HMS-600/700/800/900/1000-2T Single-phase Microinverter User Manual (2022), distributor copy2 codes, from the maker's own document
  7. [7]
    Hoymiles S-Miles Cloud User Guide V.04 (2021), Australian distributor copy2 codes, from the maker's own document
  8. [8]
  9. [9]
    Hoymiles technical note 'Wireless Connection Issues about DTU and Microinverter'2 codes, from the maker's own document
  10. [10]
    Solar Analytica Hoymiles error code list2 codes, best effort, from a secondary copy
  11. [11]
    Hoymiles Australia FAQ1 code, from the maker's own document
  12. [12]
    Hoymiles DTU-Pro User Manual V202404, distributor copy1 code, from the maker's own document
  13. [13]
    Hoymiles DTU-Pro-S User Manual V202111, distributor copy1 code, from the maker's own document
  14. [14]
    Hoymiles FAQ 'Why does my DTU show as offline?'1 code, from the maker's own document
  15. [15]
    Hoymiles HM-600/700/800 Microinverter User Manual V1.0 (2020), distributor copies1 code, from the maker's own document
  16. [16]
    Hoymiles HM-600/700/800 Microinverter User Manual V1.0 (2020), distributor copy1 code, from the maker's own document
  17. [17]
    Hoymiles HMT-1800/2250 Three-phase Microinverter User Manual V1.0 (2020), distributor copies1 code, from the maker's own document
  18. [18]
    Hoymiles HMT-1800/2250 User Manual V1.0 (2020)1 code, from the maker's own document
  19. [19]
    Hoymiles S-Miles Cloud User Guide V.04 (2021)1 code, from the maker's own document
  20. [20]
  21. [21]
    Hoymiles technical note 'Wireless Connection Issues about DTU and Microinverter' (distributor copy)1 code, from the maker's own document

Tables last updated

Hoymiles error code questions, answered

How do I read a Hoymiles error code?

Open the alarms in the S-Miles app and note the number next to each one. Then find that number in the table: neighbouring numbers share a row, so 142 sits with 141 and 305 sits with 301. Plant-level messages such as Offline or SN does not match have no number and are listed by name.

What does Hoymiles error code 141 mean?

141 is “grid overvoltage (141, 142)”. The mains voltage at the micro went above the limit in its grid profile, so it stopped until it dropped back; 142 is the same measured as a 10-minute average, usually sustained high voltage on sunny afternoons. Hoymiles says an occasional one recovers by itself; if frequent, check the grid voltage with the power operator or have the limit adjusted with their consent. An electrician measures your own cable’s voltage rise first. We rate it wait and watch. See it in the table.

What does Hoymiles error code 301 mean?

301 is “hardware error (301 to 309)”. An internal hardware fault inside that micro; on the HMS series the light goes solid red for a hardware failure. Hoymiles says a one-off that clears while the micro keeps producing needs no action, but one that repeats or does not recover goes to the dealer or Hoymiles support, which in practice means a warranty replacement. The micro cannot be repaired on site. Only that panel is affected. We rate it stop and call. See it in the table.

Do you cover my area?

We work in Adelaide, the Adelaide Hills, Gawler, the Barossa, the Fleurieu, Murray Bridge and Yorke Peninsula in South Australia, or North Brisbane, Caboolture, Bribie Island, the Sunshine Coast, Noosa and Gympie in Queensland. Check your postcode to be sure. Outside those areas, this page still tells you what your code means and how urgent it is, and a licensed electrician near you can take it from there.

What does it cost to have a Hoymiles system looked at?

For homes in our service area, the phone diagnosis is free. If it needs a visit, there is a callout fee, and it is credited against any repair or replacement we do.

Will you work on a Hoymiles system you did not install?

Yes, if it is in our service area. Most of our repair work is on systems someone else installed. We test the whole system, not just the micro that looks at fault.

Why does my Hoymiles show alarm 71 or 141 most afternoons?

Both point at high grid voltage. With 71 the micro is turning its output down, as Australian rules require, and with 141 it has stopped until the voltage drops back. An occasional one is nothing to worry about. If it happens most sunny afternoons, you are losing production: an electrician can measure the voltage rise on your own cable and report high street voltage to the network.

Why do all my Hoymiles micros show offline?

When every micro is offline at once, the micros are usually fine and the problem is the DTU: it has lost the internet, the wifi password has changed, or the serial numbers on the plant do not match. Restart the DTU and the router first. A serial number mix-up is fixed remotely by the installer, and the micros come back within about 15 minutes.

Where do the codes on this page come from?

Most come from Hoymiles’ own user manuals for the HM, HMS and HMT micros and the DTU, and its S-Miles Cloud guide. The grid transient (11 to 15) and output reduction (71 to 73) rows come from the S-Miles installer app’s alarm list as decoded by the open-source community, so their wording is approximate. Any row that could not be confirmed in a Hoymiles manual is marked best effort. Each code in the table carries a numbered reference to its document in the source list.

Written by

Joe Deionno

Started in 2017 after years of subcontracting and seeing the dodgy operators at work; set out to be the installer people could trust. Oversees every install in both states.

4.9Google · 530+ reviews 4.8SolarQuotes reviews